NETWORK APPLIANCE - NS0-093 - NETAPP ACCREDITED HARDWARE SUPPORT ENGINEER–VALID VALID BRAINDUMPS QUESTIONS

Network Appliance - NS0-093 - NetApp Accredited Hardware Support Engineer–Valid Valid Braindumps Questions

Network Appliance - NS0-093 - NetApp Accredited Hardware Support Engineer–Valid Valid Braindumps Questions

Blog Article

Tags: NS0-093 Valid Braindumps Questions, Latest NS0-093 Training, NS0-093 Latest Test Cost, NS0-093 New Exam Bootcamp, Exam NS0-093 Overview

The bundle has an Network Appliance NS0-093 exam questions and answers, desktop practice software, and web-based software. All the preparation products have been designed carefully with advice from hundreds of professional Network Appliance certified experts. This Network Appliance NS0-093 exam questions preparation material has everything to achieve success in the NetApp Accredited Hardware Support Engineer exam on the first attempt. The unique features of PrepPDF NS0-093 Preparation products have been noted. The NS0-093 pdf exam questions by PrepPDF have the most realistic Network Appliance NS0-093 exam questions. This NS0-093 pdf covers all the NS0-093 Exam Questions from the previous exam as well as the upcoming NetApp Accredited Hardware Support Engineer exam. You don't need to consult different books for the Network Appliance certification exam with the PrepPDF.

The NS0-093 certification exam consists of 60 multiple-choice questions that must be completed within 1 hour and 30 minutes. NS0-093 exam covers a variety of topics, including hardware installation and configuration, disk shelves and disk drives, storage systems, data protection, and troubleshooting. To prepare for the exam, NetApp offers a range of training courses and resources, including instructor-led courses, e-learning modules, and practice tests. Individuals who pass the NS0-093 certification exam will be able to demonstrate their knowledge of NetApp hardware support and will be well-positioned to pursue a career in this field.

The NS0-093 Certification is recognized globally and is a valuable credential for IT professionals seeking to advance their careers in the storage industry. NetApp Accredited Hardware Support Engineer certification demonstrates the candidate's expertise in NetApp hardware products and their ability to provide high-quality support to customers.

>> NS0-093 Valid Braindumps Questions <<

Latest NS0-093 Training, NS0-093 Latest Test Cost

Latest NS0-093 exam torrent can vividly embody the spirits and effort we have put into them. And the power of our NS0-093 test prep permit you to apprehend the essence of the exam. All elites in this area vindicate the accuracy and efficiency of our NS0-093 quiz guides. They have helped more than 98 percent to 100 percent of customers pass the exam efficiently. When dealing with the similar exam in this area, our former customers order the second even the third time with compulsion and confidence. That can be all ascribed to the efficiency of our NS0-093 Quiz guides. On our word of honor, these NS0-093 test prep will help you who are devoid of efficient practice materials urgently.

Network Appliance NS0-093 exam is a certification exam aimed at hardware support engineers who work with NetApp products. NetApp Accredited Hardware Support Engineer certification is offered by NetApp, a leading provider of storage and data management solutions. NS0-093 Exam is designed to test the skills and knowledge of hardware support engineers who work with NetApp products and technologies.

Network Appliance NetApp Accredited Hardware Support Engineer Sample Questions (Q42-Q47):

NEW QUESTION # 42
Which two ONTAP systems support both SSD and SAS disks? (Choose two.)

  • A. AFF A220
  • B. FAS2750
  • C. FAS8200
  • D. AFF C190

Answer: B,C

Explanation:
The following ONTAP systems support both SSD and SAS disks:
* Description:
* The FAS2750 is part of NetApp's hybrid storage array product line.
* It supports both SSDs for performance tiers and SAS disks for capacity tiers, making it suitable for mixed workloads.
1. FAS2750
* Description:
* The FAS8200 is an enterprise-level storage system that also supports hybrid configurations with both SSD and SAS drives.
* This system is designed to handle high performance and capacity needs.
2. FAS8200
* A. AFF C190:
* The AFF C190 is an all-flash system and only supports SSDs. It does not support SAS disks.
* C. AFF A220:
* Like the AFF C190, the AFF A220 is also an all-flash system that supports SSDs only.
Why Other Options Are Incorrect:
* NetApp "Hardware Universe" confirms drive support for FAS and AFF systems.
* NetApp product documentation details supported disk types for hybrid and all-flash systems.
References:


NEW QUESTION # 43
Which two tools can you use to invoke AutoSupport? (Choose two.)

  • A. NetApp Cloud Insights
  • B. the NetApp Active IQ website
  • C. CLI
  • D. the SmartSolve tool

Answer: B,C

Explanation:
To invoke AutoSupport in ONTAP, the following tools can be used:
* How to use:Run the command:
1. CLI (Command Line Interface)python
Copy code
autosupport invoke -node <nodename> -type all
* This triggers AutoSupport to collect and send logs and system information.
* How to use:Log in to the Active IQ portal and use its interface to request an AutoSupport message from the connected ONTAP systems.
2. NetApp Active IQ website
* A. NetApp Cloud Insights:
* This tool is used for monitoring and performance analysis, not for triggering AutoSupport messages.
* D. the SmartSolve tool:
* SmartSolve is used for case resolution guidance but does not invoke AutoSupport.
Why Other Options Are Incorrect:
* "ONTAP AutoSupport Guide" provides instructions for invoking AutoSupport via CLI and Active IQ.
References:


NEW QUESTION # 44
What is the recommended value for disk and CPU use when you plan an upgrade?

  • A. less than 85%
  • B. less than 70%
  • C. less than 90%
  • D. less than 50%

Answer: B

Explanation:
Upgrade Considerations for Disk and CPU Utilization:
* During an ONTAP upgrade, it is critical to ensure the system has sufficient resources to handle the upgrade process without impacting normal operations.
Recommended Threshold:
* NetApp recommends that both disk and CPU utilization should be below 70% before initiating an upgrade. This ensures that there is enough headroom for the upgrade operations and avoids performance degradation.
Steps to Verify Utilization:
* Use the system node show -fields cpu command to check CPU usage.
* Use the storage aggregate show -fields used command to check aggregate disk utilization.
NetApp Reference Documentation:
* "ONTAP Upgrade and Maintenance Guide" specifies the 70% threshold for disk and CPU usage during upgrade planning.
* The "ONTAP Performance Management Guide" provides methods for monitoring system resource utilization.


NEW QUESTION # 45
You have replaced a failed boot device. You perform boot_recovery and receive no errors. However, when the node reboots, it reports that it has no disks.
What are two possible causes? (Choose two.)

  • A. The interconnect is down.
  • B. The node is booting a lower version of ONTAP software than was last used.
  • C. The disks that are owned by this node have been marked as failed.
  • D. The SAS cables were incorrectly reconnected after reinstalling the motherboard.

Answer: B,D

Explanation:
Possible Causes for "No Disks" Error:
* A (Incorrect SAS Cabling): If the SAS cables are incorrectly reconnected or swapped after replacing the boot device, the disks may not be detected because the physical connection to the shelves is compromised. Verifying and reseating the SAS cables is essential.
* C (Lower ONTAP Version): If the node boots into an ONTAP version that is lower than the version previously used, it might not recognize the RAID labels or disk metadata created by the higher ONTAP version.
Why Other Options Are Incorrect:
* B (Disks Marked as Failed): Disks that are marked as failed would still be visible in the system, though unusable.
* D (Interconnect Down): An interconnect failure affects HA functionality but does not prevent a node from detecting its own disks.
NetApp Reference Documentation:
* Refer to the "ONTAP Boot Recovery Guide" and "SAS Cabling Guide" for steps to resolve disk detection issu


NEW QUESTION # 46
Which two steps are required to replace a drawer in a DS460c shelf? (Choose two.)

  • A. Evacuate all drives in the drawer.
  • B. Power off the shelf.
  • C. Disconnect the cable chains from the chassis.
  • D. Shut down both nodes.

Answer: A,C


NEW QUESTION # 47
......

Latest NS0-093 Training: https://www.preppdf.com/NetworkAppliance/NS0-093-prepaway-exam-dumps.html

Report this page